== Additional emergency error code meanings ==
Additions to CiA 417, part 1:
 
== 8.4 Additional emergency error code meanings ==


Devices compliant to this specification may use additional error codes, as specified in Table 4.
Devices compliant to this specification may use additional error codes, as specified in Table 4.

Aktuelle Version vom 5. Juli 2012, 16:02 Uhr

Additions to CiA 417, part 1:

8.4 Additional emergency error code meanings

Devices compliant to this specification may use additional error codes, as specified in Table 4.

Table 4 - Error codes

Error code Description Reaction
0010h CAN warning level reached <tbd>
3111h Mains over-voltage <tbd>
3121h Mains under-voltage <tbd>
3211h Over-voltage (device internal) <tbd>
3221h Under-voltage (device internal) <tbd>
FF01h Light barrier defect <tbd>
FF02h Finger protector defect <tbd>
FF03h Motion detection defect <tbd>
FF04h Application error <tbd>
FF05h Overspeed Car drive unit: fast stop
FF06h Unintended car movement (UCM) Car drive unit: fast stop