Introduction

CANopen devices compliant to this application profile shall support the Emergency service and the Emergency protocol as specified in /CiA301/.

Emergency messages are triggered by internal errors in the device. They are structured as specified in /CiA301/. The manufacturer-specific error field (msef) shall be reserved for future use. The structure of the Emergency message is specified in /CiA301/ and shown in Figure 1.

Byte 7 Byte 6 Byte 5 Byte 4 Byte 3 Byte 2 Byte 1 Byte 0
msef er eec

Figure 1 - Structure of the Emergency message

  • eec: Emergency error code
  • er: Error register (see object 1001h)
  • msef: Manufacturer-specific error code

Additional error codes